Based on 32-bit CPU: (central processing unit), high-speed intelligent ARM platform, faster operation speed, lad the technology upgrade foundation platform for future touch screen, video surveillance, one to multi control technology and wireless communication technology. 200,000 card users and 200,000 events buffer: not only all-metal-enclosed case, but also designed small metal box packaging the control panel, make more remarkable functions of anti-electromagnetic interference, anti-radiation interference to ensure system long term 24 hours use without break. Double metal hulled shielding: not only all-metal-enclosed case, but also designed small metal box packaging the control panel, make more remarkable functions of anti-electromagnetic interference, anti-radiation interference to ensure system long term 24 hours use without break.

4-layer board: professional circuit design of 4-layer board, with stronger anti-interference capability and more stable system than double-layer circuit board. Imported high-quality connecting terminals: anti-wrong connecting design, excellent anti-oxidation capability, good wiring and plug. High temperature test: ensure the lower failure rate, stronger adaptable capability in poor environment, can be used normally under environment of -40? 200,000 users and 200,000 offline event buffers storage.

Real-time uploading the Individual popedom revision. Real-time monitoring, photo display, door status display on large screen-1-5 card swiping information and photos. Multi-level dept and team set.

Flexible popedom management, individual popedom revision and upload. Emergency double shutoff, emergency manual door close. Compell to lock and unlock. Unlock by manually inputing card number+password.

First card unlocking software remote open. Unlock the door by multi-card. Normal open and normal closing at certain time. Limited card swiping times management.

Record unlocking by button record door open/close events. Normal, shift work and time attendance administration.

Functions with connecting ADCT expansion panel. Fire alarm and emergency unlocking. Functions with connecting ADCT3000 expansion panel. Can drive hardware(alarm siren, alarm light) to alarm, otherwise can only alarm on software interface or drive computer speaker to alarm. Alarm for long time unlocking, illegal break in, invalid card swiping.

Specifications of Access Control Set. ADCT3000-2 Hi-end Access Control Set (With power supply and case). Card reader input communication format. 40.5 30.5 9.6 cm. Package net weight(with carton). Control 2 doors and four card readers :Two readers for enter, the other two for exit;Two Exit button. 28 9.5 3.5 cm. Wiegand 26-40 bit (All 125KHz or 13.56MHz card reader with compatible protocol). Door opening time extending setting. 200,000 Events buffers record. High speed flash meomery, Never lose. Max distance from reader to controller. Depend on the network parameter of LAN or WAN. Specifications of Power Supply and case.

Power and rated current:one way 30W(3A) for controller and card reader; the other way 60W (5A) for electric locks. Output voltage: 12VDC (11-14V adjustable). Outside connected storage battery:7AH, 12VDC. One way for controller and card reader and the other way for electric locks.

One battery can continue offering power for controller and card reader about 24hours, while for standard electric locks, can be 3-4hours. Also can connect more storage batteries in parallel to get more continuous time. Storage battery exhaust protection voltage:9V. In order to extend the life of storage battery, and prevent the units of access control system running abnormally for the differences of the lowest operation voltage.

Two-way inter-lock protection: prevent that the door can not open due to continuous working of electric locks power when main controlled power supply gets abnormal. ADCT Access Controller Wiring Diagram. Access Controller, Power Supply, Case, Cable, Software CD, User Manual, Key. The line of electric lock to controller, it's recommended to use two-wire power line, the cross-sectional area of 1.0 mm2 or more.

If over 50 meters, it's considered to use more thick line or multiple parallel, the longest no more than 100 meters. The line of door sensor to controller, it's recommended to use two-wire power line, the cross-sectional area of 0.22 mm2 or more If no need to know door open/close status online, or door long-time not close alarming, either illegal intrusion alarming, interlock function, etc.

The door sensor can be without wiring. The line of card reader to controller, the cross-sectional area=0.22mm2, CAT. 5 or UTC are both applicable. If no need to identify the valid or invalid card by the feedback of sound and light, it can be without connecting BEEPER (blue) either LED (brown). It's better twisted-pair for lines Data0 and Data1.

The distance of card reader to controller can't be over 100meters, proposed within 80 meters. If the distance exceeds 50meters, it's proposed to bold or share as aggregate to provide power supply to card reader, which is helpful to improve the functions of card reader. The line of button to controller, it's recommend to use two-wire, the cross-sectional area 0.221mm2 or more.

TCP/IP communication line: It's the same with computer network wiring, controller connecting to switch or HUB with ordinary network cable, distance less than 100meters. The longer distance, the higher quality requirement of cable. 220V AC power cable: three-wire power supply, the cross-sectional area 1.0mm2 or more. It's required that power supply must be grounded to prevent from power interference.

You can set how many minutes late will not be counted as late. You can define the holiday period on the software administration interface. For example: to define how many minutes late or early will be counted as absent. Can specify a certain door to do time and attendance. Can specify some doors to do time attendance and access control, or some doors only do access control.

Can set the number of daily card swiping. You can set each day at least twice card swiping or four times card swiping.

Flexible Sat time and attendance setting. You can set the weekend to be Sat and Sun, or only Sun etc. Can import leave application form, flexibly add and customize the holiday name. Can input affair leaves, sick leaves, evection and yearly leaves etc. Can legally do manual sign in.

If some one didn' t swip the card or late because of forgivable reason, you can do manual sign in for him. You can check and print the report or export to a excel file.

Report include details such as on and off time, department and other informtions. You can check time attendance according to department, date etc.

Detail time and attendance summary report. Employees' s montly(or a certain period of time) time attendance report.

Also you can summer according to department or person. It can calculate how many minutes late, how many times late, how many times leave early, how many hours overtime work etc. You can choose to print in vertical or horizontal direction. Can customize the report form. You can choose to print which item, width, sequence, and even save the form so next time you can use it again.

Can set that certain person excluded from time. For example, some special position such as general manager or some position which needs go out frequently, you can set on the software to exclude them from the time attendance list. Besides normal shift, you can set additional 99 shifts.

Shift time can be set at 0:00. Shift period can be defined by yourself. Every shifts can set different card swiping times.

Each shifts can set to swipe twice, 4 times, 6 times or 8 times, and can set a specified shift as overtime work. Can calculate two kinds of overtime work mode: Postpone. Postpone over time means employee do overtime but no need to swipe overtime working card, only need to swipe card after overtime work. Example: normal shift is 17:30 off work, you can set overtime work start from 18:00, if employee swipe the card at 18:30, then 30 minutes will be counted as overtime work.

Certain time overwork, you can specify a certain time period as overwork time, for example, 19:00 to 20:00 is the overtime work period, if the employee swipe card at 19:35, then 30 minutes will be counted as overtime work, if the employee swipe the card at 21:06, then 2hours will be counted as overtime work. Swiping card fortification, disarm, alarm. Infrared door magnet anti-theft setting.

Connect with the infrared sense probe, sense organ or door magnet, if someone break in illegally, the infrared sense organ will start the alarm system. 24 hours alarm for disasters such as gas and fire.

Need to connect with the gas sense organ, smoke sense organ etc. Connect with the emergency button, if robbery happen inside the room, people can push the emergency button and alarm will be started. This item is in the category "Home, Furniture & DIY\Home Security\Other Home Security".

The seller is "fredstore13" and is located in this country: CN. This item can be shipped to United Kingdom, all countries in continental Asia, United States, European Union, Australia.

  1. Model: ADCT3000-2
  2. Brand: Unbranded/Generic
  3. Type: Control Panels & Keypads
  4. Country/Region of Manufacture: China


Hi-end TCP/IP Net Access Controller Board include Power Supply Case For 2 Door    Hi-end TCP/IP Net Access Controller Board include Power Supply Case For 2 Door